Robert S.
Jun 2021
Heating and Air Conditioning Service, Plumbing
Dan Reisdorph told me by phone that he would come to my home a few hours later. He never showed up and didn't even have the common courtesy or decency to call and let me know he was no longer coming. In my opinion he is completely unprofessional and irresponsible.
Robert R.
Aug 2014
Heating and Air Conditioning Service
unknown
Marc D.
Dec 2012
Heating and Air Conditioning Service
1. Did not install high altitude orifices
2. Did not install high altitude pressure switch
3. Did not glue together the outflow pipe (could touch it and it fell apart causing carbon monoxide to escape into the house) Dan mentioned to me that “they don’t glue them so they can access them later if needed.”
4. Inflow and outflow pipes in manual are to be 3” in diameter, he installed 2” pipes
5. Inflow and outflow piped in manual are to be min 3” in height apart at the termination, he installed directly next to each other
6. did not properly connect the condensate from the inducer housing and vent, if left unrepaired, it will cause water to fill up in inducer housing, causing severe rusting of the inducer assembly, and potentially heat exchanger damage or failure due to water being introduced into places it should not be
7. installed condensate pump on incorrect side of furnace, and is blocking access for filter replacement
8. Set the 2 stage furnace to one stage incorrectly (which is one reason I bought it- for the two stage).
9. Duct-taped two clear tubes together to get the length needed to drain condensate pump.
2. Did not install high altitude pressure switch
3. Did not glue together the outflow pipe (could touch it and it fell apart causing carbon monoxide to escape into the house) Dan mentioned to me that “they don’t glue them so they can access them later if needed.”
4. Inflow and outflow pipes in manual are to be 3” in diameter, he installed 2” pipes
5. Inflow and outflow piped in manual are to be min 3” in height apart at the termination, he installed directly next to each other
6. did not properly connect the condensate from the inducer housing and vent, if left unrepaired, it will cause water to fill up in inducer housing, causing severe rusting of the inducer assembly, and potentially heat exchanger damage or failure due to water being introduced into places it should not be
7. installed condensate pump on incorrect side of furnace, and is blocking access for filter replacement
8. Set the 2 stage furnace to one stage incorrectly (which is one reason I bought it- for the two stage).
9. Duct-taped two clear tubes together to get the length needed to drain condensate pump.
Licensing
State Contractor License Requirements
All statements concerning insurance, licenses, and bonds are informational only, and are self-reported. Since insurance, licenses and bonds can expire and can be cancelled, homeowners should always check such information for themselves. To find more licensing information for your state, visit our Find Licensing Requirements page.
*Contact business to see additional licenses.
FAQ
ALL TEMP CONTROL is currently rated 1.5 overall out of 5.
No, ALL TEMP CONTROL does not offer free project estimates.
No, ALL TEMP CONTROL does not offer eco-friendly accreditations.
No, ALL TEMP CONTROL does not offer a senior discount.
No, ALL TEMP CONTROL does not offer emergency services.
No, ALL TEMP CONTROL does not offer warranties.